Technology

The Science Behind SynapCore

How SynapCore turns a raw EEG recording into a decision-support report, and how we test it. Every step below describes what the code does today.

Signal Processing

From Raw Signal to Clinical Insight

Five stages turn a multichannel EEG recording into a structured decision-support report.

01

Raw EEG Acquisition

EEG recordings uploaded as EDF files. The pipeline uses the 19 standard channels of the 10-20 system and needs at least 15 of them to run.

02

Preprocessing

Resampling to 256 Hz, 1-45 Hz band-pass and 50 Hz notch filtering, 2-second epochs, and automatic epoch cleaning with AutoReject, which repairs or drops noisy segments.

03

Feature Extraction

Absolute and relative power in the delta, theta, alpha, beta and gamma bands, theta/beta and alpha/theta ratios, coherence between channel pairs, and complexity measures (entropy, Hjorth parameters, DFA).

04

ML Classification

LightGBM gradient-boosted classifier, hyperparameters tuned with Optuna, probabilities calibrated with a sigmoid calibrator. Evaluated with leave-one-subject-out (LOSO) cross-validation.

05

Clinical Report

A calibrated probability and the features that drove it (SHAP), written up as a structured report. Designed for clinician review, not autonomous diagnosis.

Machine Learning

ML Architecture

SynapCore uses LightGBM, a gradient-boosted decision tree model, chosen because it works well on tabular EEG features with small cohorts and its predictions can be explained feature by feature.

LightGBM Classifier

Gradient-boosted trees trained on the extracted EEG features. Each prediction comes with SHAP values that show which features pushed the probability up or down.

LOSO Cross-Validation

Leave-one-subject-out validation keeps every recording of the test subject out of training. It gives a more conservative and realistic estimate of performance on a new person than k-fold splits.

Clinical Relevance

LOSO mimics the real situation, where the model sees a patient it has never seen before. That is why we report LOSO results rather than the higher k-fold scores common in EEG-ML papers.

Validation

Performance Metrics

Neuraxis evaluated on public research datasets with LOSO cross-validation. All metrics are preliminary research results.

MetricNeuraxis-Child v1.0Ages 7-12Neuraxis-Adult v1.0Ages 18-35 · under revalidation
AUC0.650Not reported
Balanced Accuracy0.595-

Internal LOSO results on the IEEE cohort. On an independent external cohort (HBN-EEG, N=321, ages 5 to 17) Neuraxis-Child scored AUC 0.519, which is chance level. All reported metrics are preliminary research results. Research Use Only (RUO).

Data

Research Datasets

Developed and tested on publicly available EEG datasets, so the work can be checked and reproduced.

IEEE ADHD Dataset

Full dataset7-12 years

Publicly available paediatric EEG dataset used for ADHD classification research, with clinical ADHD diagnoses. Primary training and validation set for Neuraxis-Child.

TDBRAIN

N=72 (subset)18-35 years

Lifespan EEG dataset (ages 5 to 89) from the Brainclinics Foundation, Nijmegen, The Netherlands (van Dijk et al., 2022). We selected a subset of subjects within the adult ADHD age range. Used in Neuraxis-Adult validation work with LOSO cross-validation; the adult module is under revalidation.

HBN-EEG

N=3215-17 years

Healthy Brain Network resting-state EEG (105 ADHD, 216 control), used only as an independent external test of Neuraxis-Child. No HBN subject was used in training. The model scored at chance level on it (AUC 0.519).

Pre-Commercial · Research Use Only

Regulatory Status

SynapCore is a research tool. It has not been assessed by any regulator and must not be used to diagnose or treat patients.

Current status

Now

Research Use Only. Not UKCA marked, CE marked or FDA cleared.

Before clinical use

Required

Software that supports diagnosis is regulated as a medical device. SynapCore would need UKCA marking to be used in the UK, and CE marking or FDA clearance for the EU or US.

How we build it

Now

Versioned code, reviewed changes and documented, audited methods. A formal IEC 62304 process has not started yet.

Next step

Planned

Validation on clinical data with a research partner, under ethical approval, before any regulatory submission.

Working in EEG research or clinical neuroscience?

We are looking for research and clinical partners to help validate SynapCore.